Oceania Solutions Group
  • Our Products
    • AirSanitizer
    • Air Curtains
    • Air Distribution Systems
    • Air Handling Units
    • Attenuators
    • Buffer Tanks
    • Chillers
    • Cooling Towers
    • Energy Recovery Units
    • Fan Coil Units
    • Water Cooled Pac Units
  • Our Partners
    • Barcol-Air >
      • Air Distribution Systems
    • BlueBox >
      • BlueBox Epsilon Echos
      • BlueBox Omicron
      • BlueBox Kappa
      • BlueBox Tetris 2
    • Euroclima >
      • AirSanitizer
      • ETA Matic
      • ZHK INOVA AHU
      • ZHK NANO AHU
      • ZHK FI AHU
      • Double Skin FCU
      • Single Skin FCU
      • Cassettes
      • High Wall
      • Decorative Units
      • Revit Plugin
      • AHU Features
      • Seismic Testing
      • Certifications
    • HVAC Attenuation
    • IceBox
    • Komfovent >
      • DOMEKT
    • Liberty >
      • Liberty Industry
      • Liberty Swimming Pools
      • Liberty Medical
    • Mesan USA >
      • Cooling Towers
    • Reverso 361° >
      • Reverso BT
      • Reverso BT Offices
      • Reverso FS
      • Reverso HW
      • Reverso SM
      • Reverso Controller
    • Smartech >
      • Water Cooled Pac Units
    • VTS WING >
      • Air Curtains
      • WING Dark
      • WING PRO Industrial
      • Medical Facilities
      • Hospitality Venues
      • Retail Stores
      • Revit Plugin
      • FAQs
      • Shop Now
  • Downloads
  • Projects
  • Latest News
  • Contact
    • Certifications

Composite Air Handling Units for ​Hospital, Medical, Aged Care & Pharmaceutical Industries

In hospitals and throughout medical, aged care and pharmaceutical facilities, air treatment systems are an important part of the entire package of measures aimed at infection prevention. 

Contamination and germs, the stability of the air management, filter class and air tightness of the air treatment system is crucial.

Equ
ally important in aged care facilities, where residents often have a lower resistance, there are strict criteria for air quality and room conditions in order to create a minimal chance of germs and micro-organisms.

Sustainable protection of people and the environment is the main focus point when designing air treatment systems for laboratories. The system has the task of creating a stable environment and a comfortable and healthy work environment for employees.  Specific ventilation requirements apply to each type of laboratory.  Depending on the BioSafety Levels (BSL) classified in NEN-EN 12 128, ventilation rates and filter classes are ranked.
The specific advantages of using composite air handling units within these industries include:
​
  • Completely flat PET inner surface, so there are no hidden germs or places for them to move into
  • Double durable hygienic seal on panels and access hatches, with low air leakage (L1) and includes a hygiene certificate
  • Locks with overpressure protection concealed in the inspection hatch and post, leaving a smooth hygienic inner wall (VDI 3803)
  • No chance of condensation and moisture formation in unwanted places due to high insulation values (T1/TB1)
  • Attenuators provided with hygiene certificate (removable)
  • Filters are removable on the dirty side
  • High mechanical strength (D1), resulting in minimal deformation / leakage at high system pressure
  • Use of high-quality corrosion-resistant materials (composite or SS316) and hygienic components
  • Configurations with optimum accessibility or cleanability on both sides of the components are possible
  • Cleaning / disinfection with chlorine or hydrogen peroxide is possible

​ Request a quote >
Picture
Download Now

​Projects.  Solutions.  Partnerships.

We'd love to be a part of yours.  So drop us a line here>
Holbaek Sportsby Swimming Pool DENMARK
Friesland Campina Dairy Factory THE NETHERLANDS
Jacobs Douwe Egberts BELGIUM
A-Ware Food Group THE NETHERLANDS

Popular Applications for Liberty Composite Air Handling Units

Picture
Picture
Picture
Picture
​+61 7 3399 1516
[email protected]
Terms & Conditions
  • Our Products
    • AirSanitizer
    • Air Curtains
    • Air Distribution Systems
    • Air Handling Units
    • Attenuators
    • Buffer Tanks
    • Chillers
    • Cooling Towers
    • Energy Recovery Units
    • Fan Coil Units
    • Water Cooled Pac Units
  • Our Partners
    • Barcol-Air >
      • Air Distribution Systems
    • BlueBox >
      • BlueBox Epsilon Echos
      • BlueBox Omicron
      • BlueBox Kappa
      • BlueBox Tetris 2
    • Euroclima >
      • AirSanitizer
      • ETA Matic
      • ZHK INOVA AHU
      • ZHK NANO AHU
      • ZHK FI AHU
      • Double Skin FCU
      • Single Skin FCU
      • Cassettes
      • High Wall
      • Decorative Units
      • Revit Plugin
      • AHU Features
      • Seismic Testing
      • Certifications
    • HVAC Attenuation
    • IceBox
    • Komfovent >
      • DOMEKT
    • Liberty >
      • Liberty Industry
      • Liberty Swimming Pools
      • Liberty Medical
    • Mesan USA >
      • Cooling Towers
    • Reverso 361° >
      • Reverso BT
      • Reverso BT Offices
      • Reverso FS
      • Reverso HW
      • Reverso SM
      • Reverso Controller
    • Smartech >
      • Water Cooled Pac Units
    • VTS WING >
      • Air Curtains
      • WING Dark
      • WING PRO Industrial
      • Medical Facilities
      • Hospitality Venues
      • Retail Stores
      • Revit Plugin
      • FAQs
      • Shop Now
  • Downloads
  • Projects
  • Latest News
  • Contact
    • Certifications